Product Description
Single-door access controller electronic module, built-in power supply with battery support, secondary supply output 12VDC/1A with overcurrent protection, cooperation with two external access readers, power supply 18-22VAC, metal case for this module is offered separately (symbol: ME-1).
NOTICE: New access controller PR402DR has been designed as the successor of PR402-BRD access controller, therefore PR402-BRD shall be produced till the end of 2011 and then it shall be completely replaced be the PR402DR within Roger offer.
| General features |
PR312EM, PR312MF, PR612, PR622, PR602LCD-DT |
PR102DR |
PR402DR |
| 12VDC supply |
+ |
+ |
+ |
| 24VDC, 18VAC supply |
– |
– |
+
except for PR402DR-12VDC |
| Built-in EM 125 kHz proximity reader |
+
except for PR312EM |
– |
– |
| Built-in 13.56 MHz MIFARE proximity reader |
PR312MF, PR602LCD-DT |
– |
– |
| Buzzer |
+ |
– |
– |
| Keypad |
+
except for PR622 |
– |
– |
| Mountable directly on a DIN rail 35mm |
– |
+ |
+ |
| Outdoor operation |
+ |
– |
– |
| Programmable inputs/outputs |
3/3 |
2/2 |
8/4 |
| First relay output |
1.5A/30V |
1.5A/30V |
1.5A/30V |
| Second relay output |
– |
– |
5A
30V or 230VAC |
| Tamper |
+ |
– |
– |
| Programmed manually |
– |
– |
– |
| Programmed from PC |
+ |
+ |
+ |
| CE mark |
+ |
+ |
+ |
| Communication |
|
|
|
| RS485 |
+ |
+ |
+ |
| RACS Clock&Data |
+ |
+ |
+ |
| Wiegand 26..66bit |
PR602LCD-DT only |
– |
+ |
| Magstripe |
PR602LCD-DT only |
– |
+ |
| Operation with RFT1000 readers |
+ |
+ |
+ |
| Operation with long range readers |
PR602LCD-DT only |
– |
+ |
| Functionality |
|
|
|
| Number of users |
4K |
4K |
4K |
| Built-in event buffer |
32K |
32K |
32K |
| Event buffer in network equipped with CPR32-NET |
33M |
33M |
33M |
| Real time clock with battery backup |
+ |
+ |
+ |
| User groups |
+ |
+ |
+ |
| Access zones |
+ |
+ |
+ |
| Schedules |
+ |
+ |
+ |
| Access control in elevators |
+
XM-8 required |
+
XM-8 required |
+
XM-8 required |
| Local APB |
+ |
+ |
+ |
| Global APB (CPR32 required) |
+ |
+ |
+ |
| Interlocking |
+ |
+ |
+ |
| Advanced access options: two users mode, conditional access, high security mode |
+ |
+ |
+ |
| Hotel options |
– |
– |
– |
| Operation with turnstiles |
+
XM-2 recommended |
– |
+ |
| Operation with barriers |
+ |
+ |
+ |
| Random user inspection |
+ |
+ |
+ |
| Integration |
|
|
|
| Integration with T&A system (RCP Master) |
+ |
+ |
+ |
| Integration with intruder alarm system |
+ |
+ |
+ |
| Integration with CCTV system (CCTV-DVR) |
+ |
+ |
+ |