JA-111SH Bus shock and tilt detector
This may be used for safes, artworks etc. The detector uses a semiconductor tri-axial accelerometer with a digital output. Its signal processing guarantees a high immunity against false alarms.
Technical specifications
| Power from control panel bus | 12 V (9…15 V) |
|---|---|
| Current consumption in standby mode | 5 mA |
| Current consumption for cable choice | 5 mA |
| Dimensions | 55 x 27 x 16 mm |
| Classification | grade 2 |
| according to | EN 50131-1, CLC/TS 50131-2-8 |
| Operational environment | EN 50131-1 II. Indoor general |
| Operating temperature range | -10 to +40 °C |
| Also complies with | EN 50130-4, EN 55022 |