PR102DR – controller in DIN 35mm rail plastic enclosure.
PR102DR
Call For Price
Product Description
Single door access controller, adapted to connection of two, external, PRT series (Roger) readers, 12 VDC power supply, mounted inside plastic enclosure dedicated to installation on 35mm DIN rail. PR102DR is the simplest device within advanced series controllers and it offers the most essential functions, including event buffer and real time clock.
General features | PR312EM, PR312MF, PR612, PR622, PR602LCD-DT | PR102DR | PR402DR | |||||
12VDC supply | + | + | + | |||||
24VDC, 18VAC supply | – | – | + except for PR402DR-12VDC |
|||||
Built-in EM 125 kHz proximity reader | + except for PR312EM |
– | – | |||||
Built-in 13.56 MHz MIFARE proximity reader | PR312MF, PR602LCD-DT | – | – | |||||
Buzzer | + | – | – | |||||
Keypad | + except for PR622 |
– | – | |||||
Mountable directly on a DIN rail 35mm | – | + | + | |||||
Outdoor operation | + | – | – | |||||
Programmable inputs/outputs | 3/3 | 2/2 | 8/4 | |||||
First relay output | 1.5A/30V | 1.5A/30V | 1.5A/30V | |||||
Second relay output | – | – | 5A 30V or 230VAC |
|||||
Tamper | + | – | – | |||||
Programmed manually | – | – | – | |||||
Programmed from PC | + | + | + | |||||
CE mark | + | + | + | |||||
Communication | ||||||||
RS485 | + | + | + | |||||
RACS Clock&Data | + | + | + | |||||
Wiegand 26..66bit | PR602LCD-DT only | – | + | |||||
Magstripe | PR602LCD-DT only | – | + | |||||
Operation with RFT1000 readers | + | + | + | |||||
Operation with long range readers | PR602LCD-DT only | – | + | |||||
Functionality | ||||||||
Number of users | 4K | 4K | 4K | |||||
Built-in event buffer | 32K | 32K | 32K | |||||
Event buffer in network equipped with CPR32-NET | 33M | 33M | 33M | |||||
Real time clock with battery backup | + | + | + | |||||
User groups | + | + | + | |||||
Access zones | + | + | + | |||||
Schedules | + | + | + | |||||
Access control in elevators | + XM-8 required |
+ XM-8 required |
+ XM-8 required |
|||||
Local APB | + | + | + | |||||
Global APB (CPR32 required) | + | + | + | |||||
Interlocking | + | + | + | |||||
Advanced access options: two users mode, conditional access, high security mode | + | + | + | |||||
Hotel options | – | – | – | |||||
Operation with turnstiles | + XM-2 recommended |
– | + | |||||
Operation with barriers | + | + | + | |||||
Random user inspection | + | + | + | |||||
Integration | ||||||||
Integration with T&A system (RCP Master) | + | + | + | |||||
Integration with intruder alarm system | + | + | + | |||||
Integration with CCTV system (CCTV-DVR) | + | + | + |