The JA-82KRC is a basic configuration of the JA-82K control panel. The JA 82K main board provides building-block-like modularity which allows functional extensions to be made by simply plugging-in the required modules.
JA-82K Control Panel
Call For Price
Product Description
Power supply | 230 V / 50 Hz, max 0.1 A, CLASS PROTECTION II |
---|---|
Backup-battery | 12 V, 2.6 Ah, typical battery lifetime approx. 5 years (not included) |
Backup power output | maximum continuous load 0.4 A, intermittent load 1 A for 15 min’s max. |
Number of wireless device addresses | 50 (requires a JA-82R module) |
Number of hard-wired inputs | 4 (or 14 if a JA-82C is plugged in), double balanced inputs, with triggering and tamper functions, programmable section assignment and reactions |
External warning output EW* | switching to GND, max. 0.5A |
Internal warning output IW* | switching to GND, max. 0.5A |
Programmable outputs* PGX, PGY | max. 0.1 A, switching to GND, programmable function |
Event memory | 255 latest events, including date and time stamping |
Communications frequency (JA-82R) | 868 MHz |
Security grade | 2 according to EN 50131-1, EN 50131-6, and EN 50131-5-3 |
Operating environment | II. internal (-10 to +40°C) – compliant with EN 50131-1 |
Radio emissions | ETSI EN 300220 |
EMC | EN 50130-4,EN 55022 |
Electrical safety | EN 60950-1 |
Can be operated according to ERC REC 70-03 |
* these signals are also transmitted wirelessly to AC and UC receiver modules.